{"product_id":"4-foot-18w-t8-led-tube-6000k-type-a-b-frosted","title":"4-FT 18W T8 LED Tube – 6000K, Type A+B, 120–347V, Frosted Glass","description":"\u003cp data-start=\"125\" data-end=\"313\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"129\" data-end=\"158\"\u003eJC-T849-4FT-6000K-FROSTED\u003c\/strong\u003e is a 4-foot T8 LED tube designed to replace compatible fluorescent lamps in residential, commercial, retail, office, and industrial lighting applications.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"315\" data-end=\"484\"\u003eUsing 18 watts, this LED tube provides bright \u003cstrong data-start=\"361\" data-end=\"397\"\u003e6000K cool-daylight illumination\u003c\/strong\u003e through a frosted glass lens that helps reduce glare and distribute light more evenly.\u003c\/p\u003e\n\u003cp data-start=\"486\" data-end=\"855\"\u003eIts \u003cstrong data-start=\"490\" data-end=\"516\"\u003eType A+B hybrid design\u003c\/strong\u003e provides flexible installation options. It may be used with a compatible fluorescent ballast in an approved Type A installation or wired directly to line voltage in a Type B ballast-bypass installation. The lamp supports compatible \u003cstrong data-start=\"749\" data-end=\"804\"\u003esingle-ended and double-ended wiring configurations\u003c\/strong\u003e, depending on the fixture and installation method.\u003c\/p\u003e\n\u003cp data-start=\"857\" data-end=\"971\"\u003eThe wide \u003cstrong data-start=\"866\" data-end=\"894\"\u003e120–347V operating range\u003c\/strong\u003e makes the tube suitable for many standard and commercial electrical systems.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1iz91iu\" data-start=\"973\" data-end=\"989\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"991\" data-end=\"1514\"\u003e\n\u003cli data-section-id=\"e0iu84\" data-start=\"991\" data-end=\"1011\"\u003e4-foot T8 LED tube\u003c\/li\u003e\n\u003cli data-section-id=\"5diyjw\" data-start=\"1012\" data-end=\"1035\"\u003e18W power consumption\u003c\/li\u003e\n\u003cli data-section-id=\"pz9f35\" data-start=\"1036\" data-end=\"1076\"\u003e6000K cool-daylight colour temperature\u003c\/li\u003e\n\u003cli data-section-id=\"niyz9d\" data-start=\"1077\" data-end=\"1104\"\u003eType A+B hybrid operation\u003c\/li\u003e\n\u003cli data-section-id=\"1azoxea\" data-start=\"1105\" data-end=\"1171\"\u003eCompatible with approved ballast or ballast-bypass installations\u003c\/li\u003e\n\u003cli data-section-id=\"1wz5ygq\" data-start=\"1172\" data-end=\"1230\"\u003eSupports compatible single-ended and double-ended wiring\u003c\/li\u003e\n\u003cli data-section-id=\"uxep2w\" data-start=\"1231\" data-end=\"1258\"\u003eWide 120–347V input range\u003c\/li\u003e\n\u003cli data-section-id=\"10mkg0y\" data-start=\"1259\" data-end=\"1287\"\u003eFrosted glass construction\u003c\/li\u003e\n\u003cli data-section-id=\"jzav4y\" data-start=\"1288\" data-end=\"1343\"\u003eHelps provide smooth, evenly distributed illumination\u003c\/li\u003e\n\u003cli data-section-id=\"1wdkews\" data-start=\"1344\" data-end=\"1401\"\u003eDesigned to replace compatible 4-foot fluorescent tubes\u003c\/li\u003e\n\u003cli data-section-id=\"1b1cwbp\" data-start=\"1402\" data-end=\"1468\"\u003eSuitable for residential, commercial and industrial applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"t4s7oa\" data-start=\"1516\" data-end=\"1533\"\u003eBest Used For\u003c\/h2\u003e\n\u003cul data-start=\"1535\" data-end=\"1738\"\u003e\n\u003cli data-section-id=\"1q165iz\" data-start=\"1535\" data-end=\"1544\"\u003eOffices\u003c\/li\u003e\n\u003cli data-section-id=\"qcriyr\" data-start=\"1545\" data-end=\"1560\"\u003eRetail stores\u003c\/li\u003e\n\u003cli data-section-id=\"tniev2\" data-start=\"1561\" data-end=\"1573\"\u003eWarehouses\u003c\/li\u003e\n\u003cli data-section-id=\"1sqrrwe\" data-start=\"1574\" data-end=\"1585\"\u003eWorkshops\u003c\/li\u003e\n\u003cli data-section-id=\"lxyn2k\" data-start=\"1586\" data-end=\"1595\"\u003eGarages\u003c\/li\u003e\n\u003cli data-section-id=\"u0biuc\" data-start=\"1596\" data-end=\"1611\"\u003eUtility rooms\u003c\/li\u003e\n\u003cli data-section-id=\"5grfa4\" data-start=\"1612\" data-end=\"1623\"\u003eBasements\u003c\/li\u003e\n\u003cli data-section-id=\"1tvaq5r\" data-start=\"1624\" data-end=\"1633\"\u003eSchools\u003c\/li\u003e\n\u003cli data-section-id=\"a4jaz5\" data-start=\"1634\" data-end=\"1656\"\u003eCommercial buildings\u003c\/li\u003e\n\u003cli data-section-id=\"42f3ho\" data-start=\"1657\" data-end=\"1680\"\u003eIndustrial facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1yeugd3\" data-start=\"1681\" data-end=\"1712\"\u003eFluorescent fixture retrofits\u003c\/li\u003e\n\u003cli data-section-id=\"1nt4ksd\" data-start=\"1713\" data-end=\"1738\"\u003eGeneral linear lighting\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1740\" data-end=\"2205\"\u003e\u003cstrong data-start=\"1740\" data-end=\"1754\"\u003eImportant:\u003c\/strong\u003e For Type A installations, confirm that the existing ballast appears on the manufacturer’s compatibility list. Type B ballast-bypass installations require the ballast to be removed or disconnected and the fixture to be rewired according to the lamp’s wiring diagram. Confirm whether single-ended or double-ended wiring is required before installation. Electrical work should be completed by a qualified electrician in accordance with applicable codes.\u003c\/p\u003e","brand":"JENCO CANADA INC.","offers":[{"title":"Default Title","offer_id":40403154043077,"sku":"JC-T849-4FT-6000K-FROSTED","price":6.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0559\/0378\/1061\/files\/4-foot-18w-t8-led-tube-6000k-type-a-b-frosted-jenco-1.png?v=1785020145","url":"https:\/\/jencocanada.ca\/products\/4-foot-18w-t8-led-tube-6000k-type-a-b-frosted","provider":"Jenco Canada","version":"1.0","type":"link"}